LED Status
PWR
MASTER
Off
Off
Red
Off
Red
Green
Green
Off
Green
Green
LED Status
PWR
ALRM
Off
Off
Off
Red
Green
Off
LED Status
PWR
ALRM
Off
Off
Red
Red
Green
Red
Green
Off
BreezeMAX System Manual
Table 3-5: PIU LEDs
Chassis
is not connected to power.
Power is not connected or power input is out of range or PIU
card is damaged. Chassis is powered by the redundant PIU.
Power input is out of range or PIU card damaged. Chassis is
powered by the PIU
Power to PIU is OK. PIU is in redundant mode and the chassis
is powered from the other PIU.
Power to PIU is OK. The chassis is powered from the PIU.
Table 3-6: PSU LEDs
Description
No power o
r fatal damage
Power input is out of range or PSU is damaged or PSU is
inhibited by NPU.
Power is OK and PSU operates properly.
Table 3-7: AVU LEDs
Description
No 5V power input
12V power failed
One or more fans have failed
AVU operates properly
Base Station and Micro Base Station Commissioning