11.2

Connection modules for the interface module with PROFINET IO

11.2.1

CM IM PN M12, 7/8" connection module for interface modules

Order number
6ES7194-4AJ00-0AA0
Properties
The CM IM PN M12, 7/8" connection module has the following properties:
● Can be plugged in and attached with screws to the IM 154-4 PN High Feature interface
● Connecting the 1L+ and 2L+ power supplies using 7/8" cable connectors
● Connecting of PROFINET IO using M12 cable connectors
● The supply voltages and PROFINET IO can be looped through using additional sockets.
● 4 labels
Pin assignment
For details on the pin assignment of CM IM PN M12, 7/8", refer to the section
modules
Block diagram
ET 200pro distributed I/O system
Operating Instructions, 03/2013, A5E00335544-08
11.2 Connection modules for the interface module with PROFINET IO
module
.
Connection for 7/8" cable connectors (with pin insert): Feed for encoder/electronic supply, load
voltage supply
Connection for 7/8" cable connector (with socket insert): Forwarding of encoder/electronic
supply, load voltage supply
Connection for M12 cable connector (with socket insert): Feed for PROFINET IO
Connection for M12 cable connector (with socket insert): Forwarding of PROFINET IO