Migration from SIMATIC ET 200pro FC to SIMATIC ET 200pro FC-2 SIMATIC ET 200pro FC-2 FAQ-046BZQ5W November 2015 Siemens Industry Online Support Answers for industry.
Table of contents SIMATIC ET 200pro FC Concept ..............4 Introduction ................... 4 SIMATIC ET 200pro Power Modules ..............5 First generation SIMATIC ET 200pro Power Module ......5 2.1.1 SIMATIC ET 200pro FC without safety functions (6SL3235- 0TE21-1RB0) ..................5 2.1.2...
Page 3
Table of contents Migration SIMATIC ET 200pro FC 108869725 New functions when using the ET 200pro FC-2 ........ 23 6.3.1 Improved closed-loop control performance ........23 6.3.2 Expansion of the motor holding brake function ........23 6.3.3 Cyclically changing the ramp-up/ramp-down times ......23 6.3.4...
SIMATIC ET 200pro FC Concept Introduction The SIMATIC ET 200pro FC is a decentralized inverter drive product. It is part of the SIMATIC ET 200pro family of products. That is basically a compact and rugged high-performance I/O system with IP65 degree of protection. It comprises Interface Modules to connect with PROFIBUS or PROFINET environment with standard as well as failsafe functionality.
Migration SIMATIC ET 200pro FC 108869725 SIMATIC ET 200pro Power Modules First generation SIMATIC ET 200pro Power Module The original SIMATIC ET 200pro FC product had: two MLFB`s Both 1.1KW 380/480V 3 phase. 2 or 6 LED`s, depending on MLFB (Safety/Non Safety) 2.1.1...
Page 6
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Figure 3 Figure 4 Version 1.02; FAQ-046BZQ5W 30.11.2015 6/26...
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 2.1.2 SIMATIC ET 200pro FC with safety functions (6SL3235-0TE21-1SB0) Figure 5 Figure 6 Version 1.02; FAQ-046BZQ5W 30.11.2015 7/26...
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Figure 7 Second generation SIMATIC ET 200pro 2.2.1 Power Module The new SIMATIC ET 200pro FC-2 product has only one MLFB; 6SL3514-1KE13-5AE0 1.1KW 380/480V 3 phase. Figure 8 Version 1.02; FAQ-046BZQ5W 30.11.2015 8/26...
Migration SIMATIC ET 200pro FC 108869725 Figure 9 2.2.2 LED Function The SIMATIC ET 200PRO FC-2 has 2 LED`s The LEDs have different colours and flashing rates to indicate the status of the system in general, or the status of a specific function. Figure 10 LED on the converter casing Version 1.02;...
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Signal states of the LED Table 1 RDY LED RDY LED Description GREEN - on There is no fault present GREEN - slow Commissioning or reset to factory settings...
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Figure 12 USB Interface. An innovation for ET 200pro FC-2 is the USB programming interface which allows configuration via USB in the same way as other current products. Figure 13...
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Figure 15 Mounting The new Pro-2 Power Modules can be fitted on the same mounting backplane accessory as before. There are no changes in the mounting arrangements Control Units.
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Preferred Migration. Whilst the new ET 200pro FC-2 product is very similar in appearance to the previous ET 200pro FC, the firmware is completely different. The original ET 200pro FC was based on GP Pool firmware (< V4.0). The new ET 200pro FC is based on SINAMICS Pool firmware V4.7.
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Overview Hardware. The mechanical assembly of the new ET 200pro FC-2 remains identical to that of the old ET 200pro FC unit. The same mounting rail arrangement and connection of other ET200 modules for the various functions remains unchanged.
SIMATIC ET 200pro Power Modules Migration SIMATIC ET 200pro FC 108869725 Table 5 Order No. 3RK19 22-2BQ00 Sealing cap for power bus Unused connections without a sealing cap have a degree of protection of only IP54, with a sealing cap it is IP65.
Overview of the Commissioning Tools. Migration SIMATIC ET 200pro FC 108869725 Overview of the Commissioning Tools. The Commissioning tools remain unchanged compared to the old ET 200pro FC. Table 1 Operator panel for commissioning, diagnostics and controlling converters Description Order No.
Communication Interface Overview. Migration SIMATIC ET 200pro FC 108869725 Communication Interface Overview. The Communications interfaces remain unchanged compared to the old ET 200pro FC apart from the option to use the new USB interface for inverter point to point connections to a PG.
"Safe Stop 1" (SS1) Controlling the safety functions The SIMATIC ET 200pro FC-2 converter does not have its own PROFIsafe interface. The central F-CPU controls the safety functions of the ET 200pro FC-2 via a "High Feature" interface module and the PROFIsafe "F-Switch" module.
Safety Functions. Migration SIMATIC ET 200pro FC 108869725 Additional possibilities of installing the F-Switch module are listed in the Internet: 26694409 Simplified parameterization New function Just the same as for the SINAMICS G120, parameterization is performed in one channel, and only at the end of the commissioning phase is it duplicated to the second channel by pressing a button.
Drive Parameterization Migration SIMATIC ET 200pro FC 108869725 Drive Parameterization It is not possible to directly migrate from ET 200pro FC STARTER projects to an ET 200pro FC-2 as a result of the modified parameter structure. NOTE The drive must be re-commissioned again using STARTER or an IOP.
Drive Parameterization Migration SIMATIC ET 200pro FC 108869725 Changes to ET 200pro FC 6.2.1 Changed reference quantities The reference quantities (p2000 … 2004) apply in the ET200pro FC-2 as standard for all data sets. In addition, the reference quantities have been expanded by the reference temperature (p2006).
Drive Parameterization Migration SIMATIC ET 200pro FC 108869725 6.2.5 Free function blocks (FFBs) have been eliminated The Free function blocks available in the ET 200pro FC are no longer available in the ET 200pro FC-2. 6.2.6 Changes to the phase failure monitoring For the ET 200pro FC-2, the phase failure monitoring (ET 200pro FC, p291) is always active and cannot be deactivated.
Drive Parameterization Migration SIMATIC ET 200pro FC 108869725 New functions when using the ET 200pro FC-2 6.3.1 Improved closed-loop control performance The performance and stability of the individual control modes of the ET 200pro FC- 2 has been significantly improved over the closed-loop control in the ET 200pro FC 6.3.2...
Drive Parameterization Migration SIMATIC ET 200pro FC 108869725 Memory card Contrary to the ET 200pro FC (MMC card type only), for the ET 200pro FC-2 both MMC and SD memory card types can be used. Just as before, the use of a memory card is optional.
Drive Fault Messages Migration SIMATIC ET 200pro FC 108869725 Drive Fault Messages The fault messages/signals of the new ET200pro FC-2 have changed when compared to the ET200pro FC. If the fault texts are to be displayed on an HMI for diagnostic purposes, then the...