B003/B004/B006/B007 ENGINE SOFTWARE MODIFICATION HISTORY
Following a book scan job at 25-44%
reduction, the first page of a (100%) DF job is
printed out as a blank page.
When a finisher jam occurs with the 1000-
sheet Finisher, sometimes the location of the
jammed paper is not displayed.
Fusing-related SC errors happen frequently
after SP1104-1 is changed from fusing
temperature control to phase control.
When the operation switch is turned Off/On,
the value of SP6017 (Sheet Through
Magnification) is reset to default (0).
Version
2.15.04
2.06.05
2.16a.05
2.19.05
2.20
2.21
SM
CÓPIA NÃO CONTROLADA
Program No.
B0045112C
1st mass production
B0045112D
February 2001 prod.
B0045112E
March 2001 prod.
B0045112F
April 2001 prod.
B0045112G
May 2001 prod.
B0045112H
July 2001 prod.
6-85
CÓPIA NÃO CONTROLADA
SOFTWARE HISTORY
Blank page of a
B0045112 G
DF job
Jammed paper
location is not
displayed
SC error at
B0045112 H
Phase control
Value of
SP6017 is reset
to default
Effective Date
2.20
2.21