Tech Service Bulletin No. B003/B004/B006/B007 – 003
Page 2 of 2
SOLUTION:
During installation, confirm that the Left Scanner Bracket height is in specification.
If The Scanner Height Is Incorrect:
1. Remove the Scanner Unit from the machine (2 screws, 1 connector).
2. Remove the Left Cover from the Scanner Support Bracket (2 screws).
3. Loosen the Support Bracket screws (see Diagram 1, 2 screws).
4. Raise the Scanner Support Bracket so that distance A = B.
5. Retighten the Support Arm screws.
6. Confirm the height is correct.
Skewing Occurs After Installation:
1. Follow the procedure above (during installation).
Skewing Only When Using The ADF:
1. Confirm the Scanner Bracket Height is correct, if not follow the procedure outlined above.
2. If the Scanner Bracket height is correct, perform the following:
A. Remove the screw that secures the Right ADF Hinge to the copier.
B. Remove the black seal (tape) from the Right ADF Hinge.
C. Insert the screw removed in step 1 into the slotted hole (do not tighten).
E. Adjust the ADF position (back/forth) to adjust for ADF skew.
F. After skew is eliminated - tighten screw.
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA