Tech Service Bulletin No. B003/B004/B006/B007 – 025 REISSUE
ADF Position Adjustment:
1. Remove the screw [A] that
secures the Right ADF hinge to
the scanner.
2. Remove the black seal [B] from
the right ADF hinge.
3. Insert the screw [A] into the
slotted hole, but do not tighten it
yet.
4. Adjust the ADF position [C] until
the skew disappears.
5. Tighten the screws to fix the
ADF in place.
Scanner Height Adjustment:
NOTE:
The scanner height adjustment
can only be performed on
machines that have the new style
scanner support arm installed.
Examining the front securing
screw slot [B] can identify the new
style scanner arm. The screw slot
will be elongated.
1. Remove the two screws that secure the
scanner unit.
2. Place the washer(s) [A] on the scanner
stand (underneath the scanner leg) as
shown in the illustration
NOTE:
Washer Part Number 08075056, with a thickness of 0.5mm.
3. Replace the two screws and tighten.