Removal and Installation Routines
Replacing the Management Blade Lithium Battery
To permanently save system information, a lithium battery is installed on the
server blade to power the CMOS memory. When the battery voltage is too low or
the battery is empty, a corresponding error message is displayed. In this case
the lithium battery must be replaced.
– Incorrect replacement of the lithium battery may lead to risk of
!
explosion. Make sure the plus pole is facing up.
– The lithium battery must be replaced with an identical battery or with
a battery type recommended by the manufacturer (CR2032).
– Do not throw lithium batteries into the trashcan. Please dispose of
batteries in accordance with local government regulations.
The figure below shows the location of battery (1) on the management blade
board.