The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server. Service DVD A service DVD is available for service partners of Fujitsu Siemens Computers. This DVD contains the following manuals in PDF format: – the “Safety” manual –...
Page 6
Documentation Overview Preface Information/Activity Manual Features and technical data of the server blade Operating Manual Installation and initial operation, such as: – Connections to the basic unit – Operation – Configuring the server blade – Firmware update (server blade BIOS and BMC) –...
Preface Notational Conventions Notational Conventions The following notational conventions are used in this manual: “quotation marks” indicate names of chapters and terms that need to be emphasized. indicates an activity that must be performed. Ê CAUTION! indicates that, if you ignore the information given at this point, your health, the correct functioning of your system or the security of your data may be at risk.
Procedure ATTENTION! The activities described in this manual should only be performed by engineers, service personnel or technical specialists. Ê First of all please familiarize yourself with the safety instructions in the chapter “Important Notes” on page 11ff. Ê Make sure that all the manuals you need (see service DVD) are available, printing out the PDF files if necessary.
“Safety”. This device complies with the relevant safety regulations for IT equipment, including electronic office machines for use in an office environment. If you have any questions, contact your sales outlet or the Fujitsu Siemens Computers customer service center. ATTENTION! The activities described in this manual should only be performed by engineers, service personnel or technical specialists.
Page 12
Notes on Safety Important Notes ATTENTION! Transport the device only in its original packaging or in packaging which protects it from knocks and jolts. Installation and operation ATTENTION! Read the notes on installation and operation in the Operating Manual of the PRIMERGY BX600 S2 or BX600 S3 basic unit. When installing the server blade in the basic unit, beware of the energy hazard at the midplane conctacts.
Page 13
Important Notes Notes on Safety ATTENTION! Install only system extensions that satisfy the requirements and rules governing safety, electromagnetic compatibility, and telecommunica- tions terminal equipment. If you install other extensions, you may damage the system or violate these safety regulations. Information on which system extensions are suitable can be obtained from the customer service center or your sales outlet.
Page 14
Electrostatic-Sensitive Devices Important Notes Modules with electrostatic-sensitive devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When handling modules with ESDs, it is essential that you observe the following guidelines: You must always discharge static build-up, e.g. by touching a grounded object, before working with such components.
Electrostatic-Sensitive Devices Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for “environmentally friendly product design and devel- opment”. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
Page 16
Details regarding the return and recycling of devices and consumables within Europe can also be found in the “Returning used devices” manual, via your local Fujitsu Siemens Computers branch or from our recycling center in Paderborn: Fujitsu Siemens Computers Recycling Center D-33106 Paderborn Tel.
Replacement Routines ATTENTION! When working with systems and boards, make sure you observe the safety information in the chapter “Important Notes” on page 11ff. Preparation If you want to replace components which are not hot-pluggable, you must remove the server blade from the basic unit and open it. Ê...
Page 18
Preparation Replacement Routines Removing the server blade from the basic unit Ê Press the two touch points (1) to unlock the handles. Ê Open out the two handles (2) simulta- neously to disengage the server blade. Figure 2: Disengaging the server blade Service Supplement BX630 S2...
Page 19
Replacement Routines Preparation Ê Pull the server blade out of the basic unit. Figure 3: Removing the server blade from the basic unit Service Supplement BX630 S2...
Page 20
Preparation Replacement Routines Removing the housing cover Figure 4: Removing the housing cover Ê Undo the two knurled screws (1). Ê Push the housing cover as far as possible in the direction of the arrow (2). Ê Take off the housing cover. The server blade components are now freely accessible.
Replacement Routines Replacing the control panel board Replacing the control panel board The electronic elements of the control and connection panel of the server blade are located on a board that is connected to the system board of the server blade via a foil cable.
Page 22
Replacing the control panel board Replacement Routines Removing the control panel board Figure 6: Pulling off the foil cable Ê Undo the fastening screws (1) on the control panel board. Ê Loosen the clamping bracket (2) and disconnect the cable of the control panel board from the system board.
Replacement Routines Replacing processors Replacing processors You can install one or two AMD Opteron MP processors in the basic module of the server blade, see “Spare Parts and Add-On Modules” on page ATTENTION! Always use processors of the same type. All processors must have the same frequency and cache size.
Page 24
Replacing processors Replacement Routines Removing the heat sink Figure 8: Removing the dummy heat sink Ê Undo the three screws which fasten the heat sink and remove it. Installing a processor BX630 2 server blades may have two different processor sockets, figure Foxconn processor socket Tyco processor socket...
Page 25
Replacement Routines Replacing processors The following section describes how to install a processor in the Foxconn processor socket. Differences in handling a Tyco processor socket are indicated in the relevant steps. Figure 10: Processor socket variant 1: Opening the socket Ê...
Page 26
Replacing processors Replacement Routines Figure 11: Processor socket variant 1: Opening the locking frame Ê Swivel the locking lever of the processor socket upward. CAUTION! Ensure that all processor socket pins are straight. If there are damaged pins the entire server blade must be replaced. Ê...
Page 27
Replacement Routines Replacing processors Figure 12: Inserting the processor (Foxconn socket) Ê Position the new processor above the socket, and press it carefully into the socket. CAUTION! The processor can only be installed in one direction. Make sure that the recesses on the processor (A) are aligned with the corresponding positioning elements (lugs) on the socket.
Page 28
Replacing processors Replacement Routines Figure 14: Locking the processor (Foxconn socket) Ê Fold the locking frame of the processor socket down. Ê Swivel the locking lever of the socket down. Ê Lock the locking lever by pressing it under the bracket (1) on the processor socket.
Page 29
Replacement Routines Replacing processors CAUTION! When locking the Tyco processor socket, make sure that the small clips on the locking frame (A) slide under the corresponding brackets on the outer socket frame, see figure Figure 15: Locking the processor (Tyco processor socket) Service Supplement BX630 S2...
Page 30
Replacing processors Replacement Routines Installing the heat sink Please observe the following warning notices when installing a used heat sink. CAUTION! Before mounting the heat sink, check that the heat sink compound is intact. If it is not, you must do the following before reinstalling the heat sink: Ê...
Page 31
Replacement Routines Replacing processors Figure 17: Fastening the heat sink Ê Place the heat sink on the processor and fix it with the three supplied screws. Fasten the screws in the order shown in the figure. Service Supplement BX630 S2...
The data for creating the BIOS flash floppy disk is contained in the software pool http://support.fujitsu-siemens.com/com/support/downloads.html. Ê Insert an empty DOS boot disk into the floppy disk drive. Ê Copy the files containg in the ZIP archive to the DOS boot disk to create a BIOS flash diskette.
Page 36
Recovering the Server Blade BIOS Diagnosis and Maintenance CPU 1 CPU 2 Figure 19: Position of the user DIP switches (A) on the system board Ê Set switch 4 of the DIP switches (A) on the system board to ON. Ê...
Page 37
Diagnosis and Maintenance Recovering the Server Blade BIOS After a short beep, the BIOS is uploaded. The status of the flash process is displayed on the KVM console. After the flash is completed, instructions are displayed for the following procedure: Ê...
Spare Parts and Add-On Modules Diagnosis and Maintenance Spare Parts and Add-On Modules The following spare parts and add-on modules are available for the PRIMERGY BX630 2 server blade: Description Mat. No. Part No. Server Blades BX630 S2 server blade (master module) 38006712 S26361-K1131-V900 BX630 S2 server blade (slave module)
Page 39
Current information about BX630 2 spare parts and add-on modules is also provided by the FSC extranet service site (http://extranet.fujitsu-siemens.com/service). From there you can also download the interactive PRIMERGY BX6xx Illustrated Spares Catalogue. Click „Illustrated Spares Catalogue“ under the rubric „PRIMERGY“ to open the spares portal.
Abbreviations ASR&R Automatic Server Reconfiguration and Restart BIOS Basic Input-Output System Compact Disk Communication Central Processing Unit DBMS Database Management System Double Data Rate (RAM) DIMM Dual Inline Memory Module Digital Versatile Disk Error Correcting Code Error Detection Code Electromagnetic Compatibility Electrostatic Discharge Service Supplement BX630 S2...
Page 42
Abbreviations Fibre Channel Global Array Manager Hard Disk Drive Height Unit Input/Output Identification Integrated Drive Electronics Internet Protocol Local Area Network Liquid Crystal Display Light-Emitting Diode MEG-Array Manually Retention Latch Network Interface Card Service Supplement BX630 S2...
Page 43
Abbreviations Non Maskable Interrupt Peripheral Component Interconnect Prefailure Detection and Analyzing POST Power On Self Test Power Supply Unit RAID Redundant Arrays of Independent Disks Read-Only Memory Storage Area Network Serial Attached SCSI SATA Serial Advanced Technology Attachment Single Connector Attachment SCSI Small Computer System Interface Server Configuration Utility...
Page 44
Abbreviations Universal Serial Bus Video Graphics Adapter Vital Product Data Wakeup on LAN Service Supplement BX630 S2...
Index recycling devices add-on module return of devices BIOS saving energy recover server blade open remove from basic unit consumables service DVD control panel board spare parts remove 22–?? replace target group diagnostic LEDs disposal, devices documentation electrostatic-sensitive devices environmental protection ESD (modules with electrostatic- sensitive devices) labels...
Page 47
Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.