Technical data

Technical data
Electrical data (server with three power supply units with 1200 W)
Rated voltage range
Rated frequency
Max. rated current
Max. active power
Max. apparent power
Thermal dissipation
Protection class
National and international standards
Product safety and ergonomics
Electromagnetic compatibility
Emitted interference
Harmonic current
Noise immunity
CE label
according to EU directives
Approvals
Product safety
Global
Europe
Germany
USA/Canada
Japan
02
BX600
20
100 -127 V / 200 - 240 V
50 Hz - 60 Hz
100 -127 V / 11 A
200 V - 240 V / 6.5 A
100 -127 V / 2550 W
200 V - 240 V / 3600 W
3712 VA (230V)
2629 VA (110V)
12960 kJ/h
I
IEC 60950 / EN 60950 UL 1950 3rd Edition,
CSA 22.2 No. 950
FCC class A
EN 55022 class A
EN 61000-3-2
EN 55024
Low-Voltage Directive 73/23/EEC
Electromagnetic Compatibility 89/336/EEC
CB
ENEC
GS
CSA
/ CSA
US
C
VCCI
March 2006