Replacing the battery of the management blade

4.4
Replacing the battery of the management
blade
To allow permanent saving of the system information, a lithium battery is
installed which supplies the CMOS memory of the management blade with
power. You can check the battery voltage at any time via the Web interface of
the management blade, see the manual "RemoteView Management Blade". If
the capacity is too low or the battery is empty, an error message is written in the
error log file of the management blade. In this case, the lithium battery must be
replaced.
V
CAUTION!
Observe the safety notes and the information on handling batteries in
the section
Incorrect replacement of batteries can lead to risk of explosion. The
batteries must be replaced with an identical battery or with a battery
type recommended by the manufacturer.
Make sure you insert the battery correctly. The positive pole must be
on top!
Figure 22: Position of the management blade battery (arrow)
42
"Batteries" on page
Service Supplement
Replacement routines
14.