Removal and Installation Routines
Ê Press the two levers in the direction of the arrows (1) to disengage the
locking mechanism of the SDRAM socket.
Ê Position the SDRAM module so that the two notches on the bottom edge
align with the socket on the server blade (2).
Ê Insert the SDRAM module into the socket and press firmly in the direction of
the arrow (3) until it is seated correctly.
Ê Secure the SDRAM module by carefully pushing the two levers (a) into the
locking position (4).
The SDRAM modules are equipped with coded connectors so that they
i
cannot be wrongly installed.