Page 98 of 906
Acceptance tests
Table 13
TDS tone tests
Input command
BSY#loop##
C##
DIA#loop##
OVF#loop##
RBK#loop##
553-3001-211
Standard 3.00
For other than an NT8D17 Conference/TDS card, enter:
ENLL loop
4
Test the TDS loop:
TDS loop
If the system response is other than OK, see the Software Input/Output:
Administration (553-3001-311) to analyze the messages.
5
End the session in LD 34:
****
6
Using a maintenance telephone, log into the system.
See "Communicating with the Meridian 1" in the Software Input/Output:
Administration (553-3001-311) for details on accessing the system using
a maintenance telephone.
7
From the maintenance telephone, enter:
LD#34##
To test outpulsers and channels for the TDS loop, see Table 13 on
page 98
for a sample of the input commands used with the maintenance
telephone. See the Software Input/Output: Administration
(553-3001-311) for all tones that can be tested.
8
Exit LD 34 from the maintenance telephone:
****
Dial pad
equivalent
Description
279#loop##
Provides busy tone from TDS loop specified.
2##
Removes any active tone.
342#loop##
Provides dial tone from TDS loop specified.
683#loop##
Provides overflow tone from TDS loop specified.
725#loop##
Provides ringback tone from TDS loop specified.
August 2005
End of Procedure