Nortel Circuit Card Installation Manual page 98

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 98 of 906
Acceptance tests
Table 13
TDS tone tests
Input command
BSY#loop##
C##
DIA#loop##
OVF#loop##
RBK#loop##
553-3001-211
Standard 3.00
For other than an NT8D17 Conference/TDS card, enter:
ENLL loop
4
Test the TDS loop:
TDS loop
If the system response is other than OK, see the Software Input/Output:
Administration (553-3001-311) to analyze the messages.
5
End the session in LD 34:
****
6
Using a maintenance telephone, log into the system.
See "Communicating with the Meridian 1" in the Software Input/Output:
Administration (553-3001-311) for details on accessing the system using
a maintenance telephone.
7
From the maintenance telephone, enter:
LD#34##
To test outpulsers and channels for the TDS loop, see Table 13 on
page 98
for a sample of the input commands used with the maintenance
telephone. See the Software Input/Output: Administration
(553-3001-311) for all tones that can be tested.
8
Exit LD 34 from the maintenance telephone:
****
Dial pad
equivalent
Description
279#loop##
Provides busy tone from TDS loop specified.
2##
Removes any active tone.
342#loop##
Provides dial tone from TDS loop specified.
683#loop##
Provides overflow tone from TDS loop specified.
725#loop##
Provides ringback tone from TDS loop specified.