Carrier interface
553-3001-211
Standard 3.00
NTAK10 2.0 Mb DTI card
With the exception of the outpulsing signals and special signals, such as
Denmark's Flash signal and Sweden's Parking signal, the minimum duration
of any signal state is 100 ms. Some signal states can have a minimum duration
time that is longer than 100 ms.
Periodic Pulse Metering (PPM)
Periodic Pulse Monitoring (PPM) is used to collect toll charges on outgoing
CO trunk calls.
TS16 microprocessor
The functions of this microprocessor include:
receiving signaling messages supplied by the DS-30X microprocessor,
decoding these messages, and taking subsequent actions
transmitting messages to the DS-30X microprocessor
handling PPM
updating the TS16 select RAM and TS16 data RAM
providing outpulsing
receive data from the change-of-state microprocessor
transmitting AIS for CNET (France) application
Change-of-state microprocessor
The functions of this processor are:
detecting valid change of state in TS16
when a valid change has been found, passing the new abcd bits to the
TS16 microprocessor, along with five bits to indicate the associated
channel
Tx Direction
The HDB3 encoded multiplexer output is sent to the output selector, which
selects the PCM/Data output or the looped around far end data. The HDB3 is
August 2005