Figure 49
Set Mode (S M): <CR> screen
LEI:>S M
1)
Default
2)
Table
Hit <CR> to accept current value or type in a new one.
Current Mode : 1
Signaling Bits set to Default.
LEI:>
553-3001-211
Standard 3.00
NT5D33 and NT5D34 Lineside E1 Interface cards
New Mode :
However, responding to this prompt with 2 selects "Table" and allows the
user to set the A/B Bit Mode to whatever configuration the user chooses.
If "Table" is selected, the individual table values will is prompted for. See
Figure 50 on
page 297
displayed, enter <CR> to do the following:
accept the current value
enter just the AB bits (which will be copied to the CD bits)
enter a complete ABCD bit pattern
in the case of optional states, a 'N' or 'n' can be entered to indicate that
the state is not needed
Note that in D4 Framing for E1, there are no CD bits, so they will be ignored.
The user is prompted for ABCD bit values for the following states when the
table mode is selected.
Send and Receive refer to the LEI sending ABCD bits to the CPE (Customer
Provided Equipment) or receiving ABCD bits from the CPE.
Incoming and Outgoing refer to E1 digital link from the CPE point of view.
Incoming is thus an external call arriving over the digital link and accepted
by the CPE. Outgoing is a call originated by the CPE over the digital link.
Configuring the A/B Bit Signaling table is illustrated in Figure 50 and
Figure 51 on
page
298.