NT6D80 MSDL card
Figure 87
MSDL states
A newly configured MSDL automatically enters the manually disabled state.
An operating MSDL can be manually disabled by issuing the
command in LD 37 (step 1 in Figure 87).
Entering the
DIS MSDL x
disabled status and stops all system communication with the card (step 5 in
Figure 87).
Manually enabled
When the card has been manually disabled, re-enable it with the
command in LD 37 (step 2 in Figure 87).
x
August 2005
Manually disabled
1
2
Enabled
3
4
System disabled
553-5435
command in LD 37 moves the card to manually
5
DIS MSDL x
ENL MSDL