Nortel Circuit Card Installation Manual page 588

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 588 of 906
Figure 126
Two-way, loop DR, TIE trunk call connection sequence – incoming call from far-end PBX
A
Near end
System
State
Ground on tip/
battery on ring
Idle
Trunk seizure
Outpulsing
A rings
2-way voice
connection
B goes on hook
Ground on tip/
battery on ring
Idle
Ground on tip/
battery on ring
A goes on hook
Idle
553-3001-211
Standard 3.00
NT8D14 Universal Trunk card
Signal/direction
Ground on tip/
battery on ring
Low-resistance loop
Address signaling
Ringback
Battery on tip/
ground on ring
High-resistance loop
Ground on tip/
battery on ring
Ground on tip/
battery on ring
August 2005
B
Far end
System
Remarks
Far end places a low resistance between tip and ring.
Near end detects increase in loop current and makes
trunk busy to all outgoing calls.
Far end applies addressing to the trunk in the form of
battery-ground or loop pulsing, or DTMF tones.
Near end detects addressing, alerts terminal A, and
provides ringback tone to far end.
When terminal A goes off hook, near end trips ringback
tone and provides answer supervision, if required by far
end, by reversing battery and ground on tip and ring.
If far end disconnects first, it momentarily opens the loop
and then restores normal battery and ground if no near-
end answer supervision was provided when call was
establish-ed. Otherwise, it waits for the near end to
restore normal battery and ground.
Near end detects drop in loop current and restores normal
battery and ground if answer supervision was provided.
Otherwise, terminal A simply hangs up.
If answer supervision was provided, far end restores
normal battery and ground when it detects
battery/ground reversal from near end.
If near end disconnects first, normal battery is restored if
answer supervision was provided to establish call.
Otherwise, terminal A simply hangs up.
If far end detects battery/ground reversal, it
momentarily opens loop and then restores normal
battery. But, if no answer supervision was provided by
the near end when the call was established, it cannot
supply a battery reversal to signal call termination; the
person at terminal B must recognize end of call and
hang up, which will then cause the far end to restore
normal battery.
553-AAA1140

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents