Power requirements
Environment
Functional description
Switch SW4 – Carrier Shield Grounding
This switch enables for the selective grounding of the Tx / Rx pairs of the
carrier cable. Closing the switch (down position) applies Frame Ground
(FGND) to the coaxial carrier cable shield, creating a 75 ohms unbalanced
configuration. This applies only to the NTBK05CA cable.
Table 243
Switch SW4
Switch
SW 4-1
SW 4-2
Note: The usual method is to ground the outer conductor of the receive
coaxial signal.
The NTAK79 obtains its power from the backplane, drawing maximums of
2 A on +5 V, 50 mA on +12 V and 50 mA on –12 V.
The NTAK79 meets all applicable Nortel Network's operating specifications.
The NTAK79 card provides the following features and functions:
•
recovery of the 2.048 kbps data by the CEPT receiver, at signal levels
which have been attenuated by up 10 dB
•
control of CEPT line density using HDB3 which provides 64 kbps clear
channel
•
performance monitoring of the receive carrier by means of Bipolar
Violations (BPV), Slips, CRC-4 (CRC), and Frame Bit Errors (FBER)
NTAK79 2.0 Mb PRI card
Down (On)
Rx – FGND
Tx – FGND
Circuit Card
Page 751 of 906
Up (Off)
Rx – OPEN
Tx – OPEN
Description and Installation