Functional Description - Nortel Circuit Card Installation Manual

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Power requirements
Environment

Functional description

Switch SW4 – Carrier Shield Grounding
This switch enables for the selective grounding of the Tx / Rx pairs of the
carrier cable. Closing the switch (down position) applies Frame Ground
(FGND) to the coaxial carrier cable shield, creating a 75 ohms unbalanced
configuration. This applies only to the NTBK05CA cable.
Table 243
Switch SW4
Switch
SW 4-1
SW 4-2
Note: The usual method is to ground the outer conductor of the receive
coaxial signal.
The NTAK79 obtains its power from the backplane, drawing maximums of
2 A on +5 V, 50 mA on +12 V and 50 mA on –12 V.
The NTAK79 meets all applicable Nortel Network's operating specifications.
The NTAK79 card provides the following features and functions:
recovery of the 2.048 kbps data by the CEPT receiver, at signal levels
which have been attenuated by up 10 dB
control of CEPT line density using HDB3 which provides 64 kbps clear
channel
performance monitoring of the receive carrier by means of Bipolar
Violations (BPV), Slips, CRC-4 (CRC), and Frame Bit Errors (FBER)
NTAK79 2.0 Mb PRI card
Down (On)
Rx – FGND
Tx – FGND
Circuit Card
Page 751 of 906
Up (Off)
Rx – OPEN
Tx – OPEN
Description and Installation