Nortel Circuit Card Installation Manual page 518

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 518 of 906
LD 11 – Configure Data Access card. (Part 1 of 3)
Prompt
Response
REQ:
NEW CHG MOV
COPY
TYPE:
R232
R422
TN
l s c u
RNPG
<CR>
CLS
DTA
ADD
TOV
(0) - 3
OPE
(NO) YES
PAR
(SPAC) ODD EVEN
MARK
DTR
(OFF) ON
553-3001-211
Standard 3.00
NT7D16 Data Access card
required. The defaults are bracketed, and may be issued by Carriage Return
(<CR>).
August 2005
Description
Add, change, move or copy the unit
RS-232-C unit
RS-422 unit
DAC data TN. The loop (LL) must be a superloop.
Ringing number pickup group (default to zero)
Class of Service allowed for the DAC.
Data Allowed
Digit Display Allowed
Timeout value, where:
0 = no timeout
1 = 15 minutes
2 = 30 minutes
3 = 60 minutes
Operation parameter change
SPAC = space parity
ODD = odd parity
EVEN = even parity
MARK = mark parity
DTR settings, where:
ON = forced DTR
OFF = dynamic DTR
This prompt appears only if TYPE = R232

Hide quick links:

Advertisement

Table of Contents
loading