Nortel Circuit Card Installation Manual page 654

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 654 of 906
Power requirements
Environmental specifications
Foreign and surge voltage protection
553-3001-211
Standard 3.00
NT8D15 E&M Trunk card
Table 204 lists the power requirements for the E&M trunk card.
Table 204
Power requirements
Voltage
+15.0 V dc
–15.0 V dc
+8.5 V dc
–48.0 V dc
Table 205 provides the environmental specifications for the E&M trunk card.
Table 205
Environmental specifications
Parameter
Operating temperature
Operating humidity
Storage temperature
The E&M trunk card meets CS03 over-voltage (power cross) specifications
and FCC Part 68 requirements.
August 2005
Tolerance
±5%
±5%
±2%
±5 %
Specifications
0 to +60 degrees C
(32 to +140 degrees F), ambient
5 to 95% RH (non-condensing)
–40 to +70 degrees C
(–40 to +158 degrees F)
Max current
200 mA
200 mA
200 mA
415 mA

Hide quick links: