Nortel Circuit Card Installation Manual page 645

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Incoming calls
The far-end initiates calls as follows:
The ground is placed on the E lead in E&M signaling.
Dial pulses are subsequently applied from the far-end as ground open on
the E lead.
If the far-end is equipped for sending, the system can operate in any
mode (immediate start, delay dial, or wink start), as assigned on a start
arrangement basis. See Table 197.
— In immediate start mode, there is no start signal from the called
office. The seizure signal (off hook supervisory state) from the
far-end should be at least 150 ms. At the end of the seizure signal,
the far-end can start pulsing after the standard delay (normally 70 ms
minimum).
— In delay dial mode, a 256–384 ms off hook/on hook signal is
returned to the far-end immediately after receipt of the seizure
signal. When the far-end detects the on hook signal (start signal), the
far-end can start pulsing after the standard delay (normally 70 ms
minimum).
— In wink start mode, within a 128–256 ms period after receipt of the
seizure signal from the far-end, the called office transmits a 250 ms,
wink start, off hook/on hook signal to the calling office.
Table 197
Operation Mode
Operation mode
Immediate start
Delay dial
Wink start
E&M Type II signaling
Figure 151 on
page 647
and outgoing calls. Figure 152 on
NT8D15 E&M Trunk card
shows E&M Type II signaling patterns for incoming
page 648
shows Type II signaling patterns
Circuit Card
Page 645 of 906
Start arrangement
IMM
DDL
WNK
Description and Installation