Nortel Circuit Card Installation Manual page 520

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 520 of 906
LD 11 – Configure Data Access card. (Part 3 of 3)
Prompt
Response
DLNG
(ENG) FRN
KBD
(ON) OFF
WIRE
(OFF) ON
PBDO
(OFF) ON
KEY
0 SCR xxxx
1 SCR xxxx
2 TRN
3 ADL yy xxxx
4 RGA
5 SCC 0-253
6 DSP
7 MSB
553-3001-211
Standard 3.00
NT7D16 Data Access card
August 2005
Description
Data port language, where:
ENG = English
FRN = Quebec French
Keyboard dialing, where:
ON = enabled
OFF = disabled (Hayes dialing commands will still work)
Wire test mode, where:
OFF = disabled
ON = enabled
Port busy upon DTR off, where:
OFF = disabled (port busy on with DTR)
ON = enabled (port busy off with DTR)
This prompt appears only if TYPE = R232
PBDO = OFF for any RS-232-C mode besides 8, or 12
If PBDO = ON, key 7 = MSB
Key settings
Primary data DN
Secondary Data DN
Call Transfer
Autodial
Ring Again
Speed Call Controller, list number
Display
Make Set Busy
Primary and secondary data DNs must be single
appearance DNs. Feature key assignment must be as
shown here.

Hide quick links:

Advertisement

Table of Contents
loading