Nortel Circuit Card Installation Manual page 662

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 662 of 906
Table 209
Pad switching algorithm
Port B
IPE line
Universal trunk
(TRC)
IPE TIE (VNL)
Note: Transmit and receive designations are from and to the system. Transmit is from the
system to the external facility (digital-to-analog direction in the E&M trunk card). Receive is to
the system from the external facility (analog-to-digital direction in the E&M trunk card).
553-3001-211
Standard 3.00
NT8D15 E&M Trunk card
trunks. The class of service determines the operation of the switchable pads
contained in each unit. They are assigned as follows:
TRC for a 2-wire non-VNL trunk facility with a loss of greater than
2 dB, or for which impedance compensation is provided, or for a 4-wire
non-VNL facility.
NTC for a 2-wire, non-VNL trunk facility with a loss of less than 2 dB,
or when impedance compensation is not provided.
See Table 209 for the pad switching control for the various through
connections and the actual port-to-port loss introduced for connections
between the E&M trunk card and any other IPE port designated as Port B.
Figure 155 on
page 663
Port B pads
Transmit
Receive
D to A
A to D
N/A
N/A
Out
Out
In
Out
August 2005
shows the pad switching orientation.
E&M Trunk Pads
Transmit
Receive
D to A
A to D
Out
In
In
In
In
Out
Port-to-port loss (dB)
Port B to
E&M to
E&M
Port B
2.5
3.5
0
0
0
0