Nortel Circuit Card Installation Manual page 557

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Power requirements
Table 180 provides the power requirements for the NT8D09 Analog Message
Waiting Line card.
Table 180
Power requirements
Voltage
(+/-)
+ 12.0 V dc
+ 8.0 V dc
–48.0 V dc
–48.0 V dc
86.0 V ac
–150.0 V dc
Note 1: Each active ringing relay requires 10 mA of battery voltage.
Note 2: Reflects the current for ringing a single station set (or DN
telephone). There may be as many as five ringers on each line.
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning is not provided on
the NT8D09 Analog Message Waiting line card.
NT8D09 Analog Message Waiting Line card
Tolerance
0.36 V dc
0.40 V dc
2.00 V dc
5.00 V dc
5.00 V ac
3.00 V dc
Idle
Active
current
current
48 mA
0 mA
150 mA
8 mA
48 mA
40 mA
0 mA
10 mA
(Note 1)
0 mA
10 mA
(Note 2)
0 mA
2 mA
Circuit Card
Description and Installation
Page 557 of 906
Max
48 mA
280 mA
688 mA
320 mA
160 mA
32 mA