Software service changes
LD 17 – Serial port configuration parameters.
Prompt
Response
REQ:
CHG
TYPE:
CFN
IOTB
YES
ADAN
NEW TTY x
NEW PRT x
CDNO
1–16
DENS
DDEN
USER
xxx
XSM
(NO) YES
NT8D41AA Serial Data Interface Paddle Board
Once the NT8D41 SDI paddle board has been installed in the system, the
system software needs to be configured to recognize it. This is done using the
Configuration Record program LD 17. Instructions for running the
Configuration Record program are found in Software Input/Output:
Administration (553-3001-311).
Some of the prompts that are commonly used when running the Configuration
Record program LD 17, are shown in "LD 17 – Serial port configuration
parameters." on
page
ports are being used.
Description
Change configuration
Configuration type
Change input/output devices
Define a new system terminal (printer) port as device x, where
x = 0 to 15.
Use the SDI paddle board number to keep track of all ports.
Double density SDI paddle board
Enter the user of port x. The values that can be entered
depend on the software being used. See the Software Input/
Output: Administration (553-3001-311) for details.
Port is used for the system monitor.
677. These parameters must be set for each port if both
Circuit Card
Page 677 of 906
Description and Installation