Physical Description; Functional Description - Nortel Circuit Card Installation Manual

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Physical description

Switch settings
Self-test

Functional description

Common features
NTCK16 Generic Central Office Trunk cards
The NTCK16AX and NTCK16BX generic Central Office trunk cards have
eight units. Each unit connects to the shelf backplane through an 80-pin
connector. The backplane is cabled to the I/O panel which is then cabled to
the cross-connect terminal. At the cross-connect terminal, each unit connects
to external apparatus by Tip and Ring leads.
There are no option switches on the NTCK16AX and NTCK16BX generic
Central Office trunk cards. All settings are configured in software.
When the NTCK16AX and NTCK16BX trunk cards are installed and power
is applied to them, a self-test is performed on each card. The red LED on the
faceplate flashes three times, then remains continuously lit until the card is
enabled in software. If the self-test fails, the LED remains lit.
The NTCK16AX and NTCK16BX generic Central Office trunk cards
support up to eight analog Central Office trunks. They can be installed in any
IPE slot.
Both cards are exactly the same except for the Periodic Pulse Metering (PPM)
feature. The NTCK16AX card supports internal 12/16 kHz PPM but the
NTCK16BX card does not.
The NTCK16AX and NTCK16BX generic Central Office trunk cards:
support the North American loss plan
support loop start signalling
support busy tone detection and supervision on a per unit basis.
support battery reversal detection
Circuit Card
Description and Installation
Page 793 of 906