Nortel Circuit Card Installation Manual page 524

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 524 of 906
Large System and CS 1000M HG upgrade
553-3001-211
Standard 3.00
NT7D16 Data Access card
The DAC can be installed directly into slots 0, 4, 8, and 12 with no cabling
changes. If other slots are required, the upgrade must be made. Follow this
procedure to upgrade your cabling. You can upgrade the cabling
segment-by-segment, or the entire module at one time.
Note 1: Four NT8D81AA cable/filter assemblies are required to
upgrade the entire module, one assembly per segment.
Note 2: Cables are designated by the letter of the I/O panel cutout where
the 50-pin cable connector is attached. The 20-pin connectors are labeled
1, 2, and 3.
Note 3: The locations for the cable connectors are designated by the slot
number (L0-L9), and the shroud row (1, 2, and 3).
Segment 0
1
Leave cable A as is in slot L0.
2
Move cable end B-3 to L1-3.
3
Remove cable C from the backplane and connect ends C-1, C-2, and C-3
to L2-1, L2-2, and L2-3.
4
Add cable D to the I/O panel by connecting ends D-1, D-2, and D-3 to
L3-1, L3-2, and L3-3.
Segment 1
1
Leave cable E as is in slot L4.
2
Move cable end F-3 to L5-3.
3
Remove cable G from the backplane and connect ends G-1, G-2, and G-3
to L6-1, L6-2, and L6-3.
4
Add cable H to the I/O panel by connecting ends H-1, H-2, and H-3 to
L7-1, L7-2, and L7-3.
August 2005

Hide quick links:

Advertisement

Table of Contents
loading