Frame Structure - Nortel Circuit Card Installation Manual

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 902 of 906

Frame structure

553-3001-211
Standard 3.00
Appendix A: LAPB Data Link Control protocol
LAPB subset of the HDLC protocol and transmitted serially to the line at a
rate determined by the downloaded parameters.
The QPC513 card receives data serially from the line, packaged in LAPB
information frames. After determining that a block is error free the data is
supplied to the Circuit Switch Equipment as a block.
All transmissions are in frames and each frame conforms to the format shown
in Table 280 on
page
a port on the QPC513 follow these LAPB conventions:
Zero information field is permitted.
Inter-frame time fill is accomplished by transmitting contiguous flags.
This is compatible with AT&T Technical Requirement BX.25 and
ADCCP standards.
Extensions for the address field or the control field are not permitted.
This requirement imposes constraints to satellite operations.
Individual station addresses are assigned in service change for balanced
configuration. The default ESDI address is 10000000. The far-end
default address is 11000000.
The LAPB basic control field (modules 8) format is implemented.
Frame check sequence is implemented in accordance with LAPB
procedures.
August 2005