LD 14 – Trunk Data Block for NTCK16BX. (Part 1 of 2)
Prompt
REQ:
TYPE:
TN
XTRK
(See note 1 on
page
806.)
CDEN
SIGL
BTID
(See
page
807.)
SUPN
STYP
CLS
NTCK16 Generic Central Office Trunk cards
Trunk Data Block
Respond to the prompts in LD 14 as shown:
Response
NEW
COT
l s c u
XCOT
(8D)
LOP
Xx
(NO) YES
BTS
BAT
(LOL) SHL
Description
Define a new trunk unit.
Central Office Trunk
Terminal Number
Format for Large System, Call Server 1000E,
and Media Gateway 1000E, where l = loop,
s = shelf, c = card, u = unit
Type is IPE COT
Card density is 8D (default).
Loop start signaling
Enter the country busy tone ID:
Tortola, Brazil = 10
Mexico = 10 or 08 (depending on CO)
Singapore = 11
Ireland = 3 or 9 (depending on CO) Kuwait,
Chile, Venezuela, Indonesia, Thailand,
Korea = 06. Argentina = 12 or 07, Turkey = 14
Supervision yes (no)
Busy tone supervision enabled
Loop break supervision enabled
Attenuation Pads In, (Out)