The MG 1000S 10BaseT port can run in Normal mode or Survival mode. In
Normal mode, the MG 1000S does not provide access to maintenance or
alarm management.
External connections to the 10BaseT port are provided by a 15-pin connector
located on the backplanes of the Call Server and MG 1000S systems.

MG 1000S/Expansion card slot assignment

The MG 1000S and MG 1000S Expansion contain physical card slots,
numbered 1 to 10. See Figure 174 on
page 823
and Figure 175 on
page
824.
When configuring the system, the physical card slot numbers must be
transposed to "logical" card slot numbers. For example, to configure a card
physically located in Slot 2 of the first MG 1000S, use logical Slot 12. To
configure a card physically located in Slot 2 of the second MG 1000S, use
logical Slot 22. See Table 261 on
page
822.