Nortel Circuit Card Installation Manual page 443

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Auto-dial capability This feature is required when the modem is used for
outbound modem pooling. It allows the modem to go off-hook and dial the
remote number (such as Smartmodem Hayes-2400 or Bizcomp).
Auto-reset capability This feature is required when the modem is used for
outbound modem pooling. The modem should execute auto-reset when the
DTR lead goes OFF. As a result, the modem must reset all its internal
parameters to the default values. This feature prevents the users of the modem
pool from modifying the modem's default parameters to inappropriate values.
Configuring modems for mode 0
To configure Hayes modem 2400, enter the following commands:
AT&D2&W
ATVl&W
ATQ&W
ATEl&W
ATSO= 1&W
AT&Cl&Sl&W
AT&J&W
ATB1&W
AT&D3&W
Since the default parameters are programmable using commands, there is no
guarantee that users will not change them.
To configure Bizcomp 1200 modem, set the following parameters in LD11:
DEMDTE
PRMOFF
DTROFF
HOTOFF
To configure MULTI MODEM 224E modem, set the configuration
switches as follows:
switches 3 and 8 to DOWN position
all other switches to UP position. Switch 7 should be UP when using
RJ-11 jack.
NT7D16 Data Access card
Circuit Card
Page 443 of 906
Description and Installation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents