Nortel Circuit Card Installation Manual page 417

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Manually controlled maintenance
Use manual maintenance commands found in the following programs to
enable, disable, reset, get the status of, and perform self-tests on the MSDL
card:
Input/Output Diagnostic Program LD 37
Program LD 42
Link Diagnostic Program LD 48
PRI D-channel Diagnostic Program LD 96
For a complete discussion of these programs, refer to Software Input/Output:
Administration (553-3001-311).
Note 1: Enter commands after the dot (.) prompt.
Note 2: The "
the card number.
Enabling the MSDL
Enter
ENL MSDL x
has not been previously downloaded or if the card version is different from
the one on the system disk, the software is downloaded and the card is
enabled.
To force software download and enable the card, enter
This command forces the download of the MSDL base code and the
configured peripheral software even if it is already resident on the card. The
card is then enabled.
To enable a disabled MSDL and its ports, enter
command downloads all peripheral software (if required) and enables any
configured ports on the card. This command can be issued to enable some
manually disabled ports on an already enabled MSDL.
NT6D80 MSDL card
" in the commands below represents the DNUM value of
x
to enable the MSDL manually. If the MSDL base code
Circuit Card
Page 417 of 906
ENL MSDL x FDL
. This
ENL MSDL x ALL
Description and Installation
.