Nortel Circuit Card Installation Manual page 779

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Table 250
Digital Pad - values and offset allocations (Part 1 of 2)
PAD SET 0
Offset
0
1
2
3
4
5
6
7
8
message format; eight are assigned to voice/data (64 Kbps), one to signaling
(8 Kbps), and one is a data valid bit (8 Kbps).
The incoming serial bit stream is converted to 8-bit parallel bytes to be
directed to padding control. The signaling bits are extracted and inserted by
the A07 signaling interface circuitry. Timeslots 0 and 16 are currently unused
for PCM.
Digital PAD
The software selects A-Law or µ-Law and one of 32 possible PAD values for
each channel. These values are provided in a PROM through which the data
is routed. The idle code for A-Law is 54H and for µ-Law is 7FH. The
unequipped code is FFH for both A-Law and µ-Law.
As the idle code and unequipped code can be country dependent, the software
instructs the NTBK50 to use different codes for each direction. The 32 digital
pads available are illustrated in Table 250 on
attenuation levels (1.0dB is 1 dB of loss and –1.0 dB is 1 dB of gain.
PAD
0.6 dB
1.0 dB
2.0 dB
3.0 dB
4.0 dB
5.0 dB
6.1 dB
7.0 dB
8.0 dB
NTBK50 2.0 Mb PRI card
page
779. The values shown are
PAD SET 1
Offset
0
1
2
3
4
5
6
7
8
Circuit Card
Description and Installation
Page 779 of 906
PAD
0.0 dB
-1.0 dB
-2.0 dB
-3.0 dB
-4.0 dB
-5.0 dB
-6.0 dB
-7.0 dB
-8.0 dB