Conference Cards; Testing Conference Cards; Procedure - Nortel Circuit Card Installation Manual

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 90 of 906
Acceptance tests

Conference cards

553-3001-211
Standard 3.00

Procedure 2

Testing conference cards

Use this procedure to test a conference card or to test the conference function
of an NT8D17 Conference/TDS card.
1
Log into the system:
LOGI (password)
2
Request the status of a loop on the conference card:
LD 38
STAT loop
Conference status is formatted as follows:
CNFC n DSBL n BUSY
"n" represents the number of conference groups disabled and busy
CHAN n DSBL n BUSY
"n" represents the number of channels disabled and busy
UNEQ
card is not equipped in the system
DSBL
card is disabled in software
3
If the conference card loop is disabled, enable it.
For an NT8D17 Conference/TDS card, enter:
ENLX loop
(the conference loop is the odd loop of the conference/TDS loop pair)
Note: The conference/TDS card is not enabled automatically when it is
inserted. You must enable the card with the command ENLX. (This
command is used in LD 34 and LD 46 to address even loops and in LD 38
to address odd loops.) Enabling the loops with the command ENLL does
not enable the hardware for the card.
For other than an NT8D17 Conference/TDS card, enter:
ENLL loop
(the conference loop must be an even loop for cards other than the
NT8D17)
If the system response is other than OK, see the Software Input/Output:
Administration (553-3001-311) to analyze the messages.
August 2005

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents