Nortel Circuit Card Installation Manual page 809

Nortel networks circuit card description and installation
Table of Contents

Advertisement

LD 97 – Defining Loss Switching mode.
Prompt
Response
REQ:
CHG
TYPE:
SYSP
...
NATP
YES
LD 14 – Defining Loss Switching Class Of Service.
Prompt
Response
REQ:
CHG
TYPE:
COT
XTRK
XCOT
SIGL
LOP
...
CLS
LOL
NTCK16 Generic Central Office Trunk cards
Therefore the following steps must be followed when the Generic XFCOT is
installed:
1
Define Loss Switching mode. Respond to the prompts in LD 97 as shown.
Description
IPE system parameters configuration
Select North American transmission plan
Note: The default to the NATP prompt is NO, and
therefore this prompt must always be checked during
installation.
2
Define Loss Switching Class Of Service. Respond to the prompts in LD 14
as shown.
Description
LOL= Long Line
Note: The XFCOT uses the CLS Long Line (LOL) and
Short Line (SHL) for Loss Switching purposes and that
the card and trunk type is different from the XUT.
Circuit Card
Description and Installation
Page 809 of 906
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents