Nortel Circuit Card Installation Manual page 810

Nortel networks circuit card description and installation
Table of Contents

Advertisement

Page 810 of 906
Trunk to Trunk connection
Call disconnect
553-3001-211
Standard 3.00
NTCK16 Generic Central Office Trunk cards
Equivalencies
The following equivalencies do apply:
XFCOT COT SHL is equivalent with XUT COT TRC
XFCOT COT LOL is equivalent with XUT COT NTC.
The entries TRC and NTC will no longer be allowed for the Generic XFCOT.
When any disconnect supervision is configured (CLS = BAT, BTS) the Loop
Start Trunk of the Generic XFCOT will be marked as having disconnect
supervision and will therefore follow the same rules as a Ground Start Trunk.
There is no configuration involved for this operation.
When any disconnect supervision is configured (CLS = BAT, BTS) the Loop
Start Trunk will be released when the disconnect signal is received. This will
apply also in call states such as ringing, camp-on, DISA, and Meridian Mail.
There is no configuration involved for this operation.
August 2005