HVAC
HVAC System - Manual
1-15
Functional Check (cont'd)
Step
Action
Normal Result(s)
Abnormal Result(s)*
1.
Place the mode control knob
• The blower motor speed is
• There is airflow from the heater
in the MAX A/C setting.
LOW to HIGH.
and/or defroster outlets.
2. Place the temperature control
• There is no airflow from the
• There is no airflow from the
knob in the COLD setting.
heater outlets.
A/C outlets.
3.
Place the blower motor knob
• There is airflow from the
• Temperature does not change.
in the LOW to HIGH setting.
A/C outlets.
• No blower motor speed change.
• There is no air flow from the
• Blower motor speed inop.
defroster outlets.
• Refer to Cooling Insufficient -
• Temperature from the center
A/C Inoperative, System
A/C outlet should drop 11 °C
Performance Test, Air Delivery
3
(20°F) from the temperature
Improper, Temperature Control
outside the vehicle.
Inoperative or Blower Motor
• A noticeable blower speed
Inoperative at Any Speed.
increase occurs from the
following settings:
• LOW
• MEDIUM LOW
• MEDIUM HIGH
• HIGH
• The outlets hold their position
during high blower motor speed
and are moveable by hand.
1. Place the mode control knob
• The blower motor speed
• There is airflow from the heater
in the NORMAL A/C setting.
is HIGH.
and/or defroster outlets.
2. Place the temperature control
• There is no airflow from the
• There is no airflow from the
knob in the COLD setting.
heater outlets.
A/C outlets.
3.
Place the blower motor knob
• There is airflow from the A/C
• Temperature does not change.
in the HIGH setting.
outlets.
• No blower motor speed change.
4
• There is no air flow from the
• Refer to Cooling Insufficient -
defroster outlets.
A/C Inoperative, System
• Listen for a reduction of air
Performance Test, Air Delivery
noise due to the recirculation
Improper, Temperature Control
door closing.
Inoperative or Blower Motor
• Engagement of the detent is felt
Inoperative at Any Speed.
in each mode control setting.
1. Place the mode control knob
• The blower motor speed
• Blower motor speed inop.
in the Bl-LEVEL A/C setting.
is HIGH.
• Airflow from the heater outlets.
2. Place the temperature control
• There is airflow from the heater
• No airflow from the A/C outlets.
knob in the COLD setting.
outlets.
• No engagement of the detent
3.
Place the blower motor knob
• There is airflow from the
is felt.
5
in the HIGH setting.
A/C outlets.
• Refer to Blower Motor
• There is minimum air flow from
Inoperative at Any Speed,
the defroster outlets.
Cooling Insufficient - A/C
• Engagement of the detent is felt
Inoperative, Air Delivery
in each mode control setting.
Improper, Temperature Control
Inoperative.
1.
Place the mode control knob
• The blower motor speed
• Blower motor speed inop.
in the VENT setting.
is HIGH.
• Airflow from the heater and/or
2. Place the temperature control
• There is no airflow from the
defroster outlets.
knob in the COLD setting.
heater outlets.
• No airflow from the A/C outlets.
3.
Place the blower motor knob
• There is airflow from the
• No engagement of the detent
6
in the HIGH setting.
A/C outlets.
is felt.
• There is no air flow from the
• Refer to Blower Motor
defroster outlets.
Inoperative at Any Speed,
• Engagement of the detent is felt
Cooling Insufficient - A/C
in each mode control lever
Inoperative, Air Delivery
setting.
Improper or Temperature Control
Inoperative.