Brakelight Switch; Headlight Dimmer Switch - Arctic Cat 2015 ZR 5000 Service Manual

Hide thumbs Also See for 2015 ZR 5000:
Table of Contents

Advertisement

4. Install the resonator and secure using existing hard-
ware.
 NOTE: At this point, fill and bleed the oil and cool-
ing systems.

Brakelight Switch

TESTING/REMOVING
1. Disconnect the brakelight switch grey and brown
two-wire connector (located near the brake lever).
2. To test the brakelight switch, connect one tester lead
to the brown terminal; then connect the other lead to
the black terminal.
3. With the brake lever compressed, the meter must
read 1 ohm or less resistance. With the brake lever
released, the meter must read OL (open). If the meter
does not read as specified, the brakelight switch is
defective and must be replaced.
4. To remove the switch, remove all brake fluid from
the reservoir; then remove the torx-head screws
securing the reservoir to the piston assembly. Pry the
brake switch from the piston assembly.
YM-055A
INSTALLING
1. Press the switch into the brake lever assembly mak-
ing sure it is fully seated.
2. Position the O-ring into the reservoir; then secure the
reservoir to the piston assembly using the existing
screws. Tighten securely.
3. Connect the switch harness to the main wiring har-
ness. Position the wires so they will not be either
pinched or come in contact with any moving compo-
nents. Start the engine and check the switch for
proper operation.

Headlight Dimmer Switch

 NOTE: At this point, remove the handlebar pad (if
applicable).
REMOVING/TESTING
1. Remove the four screws securing the left-side han-
dlebar control assembly; then remove the control
assembly from the handlebar.
2. Disconnect the HI/LO beam harness from the switch.
3. With the switch in the LO beam position, connect
one ohmmeter lead to pin (A) and the other ohmme-
ter lead to pin (C). The meter must read 1 ohm or less
resistance.
XM207
4. With the switch in the HI beam position, connect one
ohmmeter lead to pin (B) and the other ohmmeter
lead to pin (C). The meter must read 1 ohm or less
resistance.
XM206
CM109A
143

Advertisement

Table of Contents
loading

Table of Contents