Field Service Ver. 8.0 Jun. 2008
C. Reinstall procedure
[1]
3.5.18
Replacing the imaging unit
A. Periodically replaced parts/cycle
• Imaging unit Y/M/C: Every 100,000 prints
• Imaging unit K: Every 300,000 prints
NOTE
• Although the procedure shown below is for the replacement of the imaging unit K,
use the same procedure to replace other imaging units Y/M/C.
B. Removal procedure
1. Open the lower front door.
2. Remove the waste toner box.
See P.48
1. Install the new waste toner box [1],
and close the lower front door.
A00JF2C509DA
3. Release the securing lever [1] for the
imaging unit.
[1]
A00JF2C510DA
3. Periodical check