GENERATOR
UPPER
MOUNTING BOLTS
GENERATOR
MOUNTING
BRACKET
8C - 6
CHARGING SYSTEM
REMOVAL AND INSTALLATION (Continued)
Fig. 3 Remove/Install Generator—5.2L/5.9LEngine
Fig. 4 Remove/Install Generator—4.0LEngine
(6) Reverse removal procedures to install. Tighten
generator hardware as follows:
• Generator mounting bolt 5.2L/5.9L engines - 41
N·m (30 ft. lbs.)
• Generator pivot bolt/nut 5.2L/5.9L engines - 41
N·m (30 ft. lbs.)
• Generator mounting bolt 4.0L engine - 55 N·m
(41 ft. lbs.)
• Generator pivot bolt/nut 4.0L engine - 55 N·m
(41 ft. lbs.)
• Battery terminal nut - 8.5 N·m (75 in. lbs.)
• Ground terminal nut - 8.5 N·m (75 in. lbs.)
• Harness holddown nut - 8.5 N·m (75 in. lbs.)
• Field terminal nuts - 2.8 N·m (25 in. lbs.)
GROUND
FIELD TERMINALS
TERMINAL
(-)
(B+) TERMI-
NAL
Fig. 5 Remove/Install Generator Connectors—
CAUTION: Never force a belt over a pulley rim
using a screwdriver. The synthetic fiber of the belt
can be damaged.
CAUTION: When installing a serpentine accessory
drive belt, the belt MUST be routed correctly. The
water pump will be rotating in the wrong direction if
the belt is installed incorrectly, causing the engine
to overheat. Refer to belt routing label in engine
compartment, or refer to Belt Schematics in Group
7, Cooling System.
(B+)
WIRE HARNESS
INSULATOR
TERMINAL
HOLDDOWN
Typical