Alarm Indications on 30DTI
FAULT
CAUSE
On or Off
Abnormal operation
of DTI card
On
No PCM signals
arrive from the dis-
tant office
On
Frame Alignment
signals from the
distant office can-
not be received
On
Multi Frame Align-
ment signals from
the distant office
cannot be received
On
Frame Alignment
signals cannot be
sent to the remote
PBX
– 423 –
CHAPTER 5 OPERATION TEST
FAULT
ACTION
1
Confirm the programming data:
CM05 Y=0/Y=1, CM07 Y=01.
2
Check to see if the SENSE switch
is set as per the AP number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch
3
(Down→Up→Down)
If the fault cannot be cleared,
4
replace the card.
1
Check to see if the line is correctly
connected to the DTI card.
2
Plug and unplug the DTI card.
Repeat this two or three times.
1
Check the receive line and exter-
nal equipment.
2
Replace the remote DTI card.
1
Check the receive line and exter-
nal equipment.
Replace the remote DTI card.
2
1
Check the transmission line and
external equipment.
2
Replace the DTI card.