MP built-in SMDR Programming
For local office or tandem office, in addition to the programming of MP built-in SMDR, do the following
programming. For details of the MP built-in SMDR, refer to Station Message Detail Recording (SMDR)
of Feature Programming Manual.
NOTE:
When the system provides an AP00 card (CM05 Y=0 second data=04 is assigned), the MP
built-in SMDR cannot be provided.
START
CM08
Provide the system with MP built-in SMDR.
NOTE:
Not provide the system with Centralized Bill-
ing-CCIS for Center Office.
Provide the system with Centralized Billing-
CCIS for Local Office.
Specify whether the Office number is sent to
Center Office for Centralized Billing-CCIS.
NOTE:
A
DESCRIPTION
Do not assign CM40 Y=00>14
when using MP built-in SMDR in
Local Office of Centralized Billing-
CCIS.
When the network adopts Open
Numbering Plan, set the office num-
ber by CMA7 Y=06.
CHAPTER 3 SYSTEM DATA PROGRAMMING
(1)
800
(2)
0: MP built-in SMDR
(1)
368
(2)
1 : Not provided
INITIAL
(1)
378
(2)
0: To provide
(1)
801
(2)
0 : To send
1 : Not sent
– 208 –
CENTRALIZED BILLING-CCIS
DATA
NWA-008853-001 Rev.3.0
97ch3003.fm