NEC NEAX 2000 IPS System Manual page 206

Internet protocol server ccis system manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

A
CMD003
Allow the maximum number of Call Record
sending to SMDR which is set to "5" by
CMD001>80/100/120/140.
NOTE:
When the data is set to 1-27000, ex-
ternal alarm of memory overflow is
available, if CM44, 2nd data=3002
is assigned.
Assign the maximum number of Call Record
for a local office of Centralized Billing-CCIS.
NOTE:
When the data is set to 1-27000, ex-
ternal alarm of memory overflow is
available, if CM44, 2nd data=3000
is assigned.
Assign the maximum number of Call Record
sending to SMDR/PMS which is set to "4" by
CMD001>80/100/120/140.
NOTE:
When the data is set to 1-27000, ex-
ternal alarm of memory overflow is
available, if CM44, 2nd data=3001
is assigned.
B
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
(1)
24
(2)
0
1-27000: 1-27000 calls
(1)
26
(2)
0
1-27000: 1-27000 calls
(1)
29
(2)
0
1-27000: 1-27000 calls
– 192 –
CENTRALIZED BILLING-CCIS
DATA
: No limitation
: No record
: No record
NWA-008853-001 Rev.3.0
97ch3003.fm

Advertisement