NEC NEAX 2000 IPS System Manual page 208

Internet protocol server ccis system manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

C
CM12
Specify to each station whether a station is
controlled by AP00 card or not.
[Series 3400 software required]
NOTE 1:
In billing features using AP00 card, a maximum of 504 stations can be controlled by AP00
card. When 505 or more stations are accommodated in a system, you have to specify to
each station whether a station is controlled by AP00 card or not.
NOTE 2:
When billing features using AP00 card are provided in a system that has 505 or more sta-
tions, set the 2nd data 0 or 1 to all stations.
NOTE 3:
You can confirm the stations assigned by CM12 Y=49. Execute CM12 Y=91 10 minutes
after AP initialization completed. Enter the first data which was assigned by CM12 Y=49,
the system displays the second data. Check CM12 Y=49 data setting when NONE is dis-
played even though a station is set as a controlled station by AP00 card.
CM12 Y=91 (Confirmation of stations controlled by AP00 card)
(1) X-XXXX: Station No.
(2) 000-503: Controlled Station No. 000-503
END
DESCRIPTION
AP00 INITIAL
NONE : Not controlled
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=49
(1)
X-XXXX: Station No.
(2)
0 : Not controlled
1 : Controlled
3 : Only 504 stations are controlled in
order of station registration
(The stations after the 504th are not
controlled)
– 194 –
CENTRALIZED BILLING-CCIS
DATA
NWA-008853-001 Rev.3.0