NEC NEAX 2000 IPS System Manual page 351

Internet protocol server ccis system manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

D
CM8A
STEP 3
Assign the starting time for the Toll
Restriction and Route Pattern
number to the Time Pattern num-
ber assigned by Step 2. Set the
Starting Time as shown below.
Example: To Set the 7:00 AM to 9:00 PM for
the Toll Restriction, enter the fol-
lowing starting times one by one.
0700 (7:00 AM-7:30 AM)
0730 (7:30 AM-8:00 AM)
0800 (8:00 AM-8:30 AM)
2030 (8:30 AM-9:00 AM)
STEP 4
Assign the TR Pattern number to
the Route Pattern number assigned
by Step 3.
STEP 5
Assign the Toll Restriction pattern
number (assigned by CM81) to TR
Pattern number assigned by Step 4.
END
DESCRIPTION
. .
.
CHAPTER 3 SYSTEM DATA PROGRAMMING
TRUNK-TO-TRUNK RESTRICTION-CCIS
Y=2000-2007 Time Pattern No. 00-07
(1)
XX ZZ (Starting Time)
XX : 00-23 (Hours)
ZZ : 00/30 (Minutes)
(2)
0000-0255 (Route Pattern No. 000-255)
If Tenant Pattern is required, set 1000-1015
(Tenant Pattern No. 00-15).
Y=0000-0255
Route Pattern No.000-255
(1)
1
(2)
XXX 00 (TR Pattern No.)
XXX: 000-255: TR Pattern No.
Y=5000-5255 TR Pattern No. 000-255
(1)
000
(2)
00-15 : Toll Restriction Pattern No. 00-15
– 337 –
DATA
NWA-008853-001 Rev.3.0
97ch3005.fm

Advertisement

Table of Contents
loading

Table of Contents