AUTOMATIC RECALL-CCIS

General Description
This feature works as a time reminder. When an Attendant-handled call through CCIS remains on hold,
camped-on, or ringing unanswered for a fixed interval, the Attendant is automatically alerted.
Station Application
Attendant Console
Programming
START
CM41
Specify the timing for Automatic Recall.
If no data is set, the following timing will be
applied:
Attendant Recall
Non Exclusive Hold
Exclusive Hold
Transfer Recall
Attendant Hold Recall – 31.2-33.6 seconds
Camp-On Recall
END
Operating Procedure
No manual operation is required.
DESCRIPTION
– 31.2-33.6 seconds
– 60-64 seconds
– 236-240 seconds
– 24-28 seconds
– 24-32 seconds
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=0
(1)
00
: Attendant Recall
(2)
01-14: 2.4-33.6 seconds
(2.4 second increments)
15-24: 38.4-124.8 seconds
(9.6 second increments)
(1)
11
: Attendant Hold Recall
(2)
01-14: 2.4-33.6 seconds
(2.4 second increments)
15-24: 38.4-124.8 seconds
(9.6 second increments)