NEC NEAX 2000 IPS System Manual page 333

Internet protocol server ccis system manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

B
CM85
Specify the maximum number of digits dialed
by the calling party. The maximum number of
digits including the area codes should be as-
signed to each area code.
CM8A
Assign the area code to be restricted and the
Toll Restriction Pattern number assigned by
CM81 to the Area Code Development Pattern
number assigned by CM35 Y=76. For exam-
ple, to provide the Trunk Restriction Class
RCB, RCC, RCD, RCE, RCF, RCG and RCH
with the Toll Restriction for Area Code "00":
• Area Code=00
• Toll Restriction Pattern=05
(See Toll Restriction Pattern Table on
CM81.)
If the Toll Restriction Pattern for the same area
code is changed according to the Tenant, Date,
and Time, add the required patterns (Tenant,
Date, and Time) to the area code.
Area
Code
C
DESCRIPTION
Time
Pattern
2000
-2007
4000
-4004
3000
-3003
Data
Pattern
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=0-4
Area Code Development Pattern No. 0-4
assigned by CM8A Y=A000
(1)
X-X...X: Area Code dialed
(2)
01-24 : 1-24 digits
25-79 : 25-79 digits
Y=4000-4004
Area Code Development Pattern No. 0-4
(1)
X-X...X: Area Code (Maximum 8 digits)
(2)
B000-B015: Toll Restriction Pattern No.
1000
-1015
Tenant
Pattern
– 319 –
TOLL RESTRICTION-3/6 DIGITS-CCIS
DATA
(Maximum 8 digits)
00-15
Toll Restriction
Pattern 00-15
0000
-0255
Route
Pattern
-5255
TR
Pattern
NWA-008853-001 Rev.3.0
5000