• The 2000 IPS must be a subordinate office.
• A network must include one 2400 IPX at least. An network station (NS) can be accommodated to
2400 IPX and its neighboring 2000 IPS. The connection via Event based CCIS is not available.
FUNCTION
Accommodate NS
Call NS
• For the network station number in integrated numbering plan through CCIS network, the access code
for network station number must be set by CM20>811-818.
2000 IPS-1
2400 IPX
CCIS
CCIS
2000 IPS-1
2400 IPX
×
×
×
×
CHAPTER 3 SYSTEM DATA PROGRAMMING
NETWORK STATION NUMBER-CCIS (FCCS)
2000 IPS-2
2000 IPS-3
CCIS
CCIS
2000 IPS-2
×
×
– 301 –
2000 IPS-4
×
: Available
–: Not available
2000 IPS-3
2000 IPS-4
×