Specifications; Devicenet Communications Unit (Model: 3G3Ax-Rx-Drt-E) - Omron RX Series User Manual

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

12-16 DeviceNet Communications Unit
(Model: 3G3AX-RX-DRT-E)

12-16-1 Specifications

Unit type
Model
Mounting
Dimensions
[Width x Height x Depth]
Weight
Operating ambient
temperature
Operating ambient humidity
Storage ambient temperature
Vibration resistance
Environment
Dielectric strength
Location
Conformance to EMC and
electrical safety standards
Enclosure rating
Communications protocol
Certification
DeviceNet profile
Supported connections
DeviceNet
interface
Communications power
supply
Unit device address range
Supported baud rates
Default connection path
DeviceNet
Supported assemblies
configuration
EDS file
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Item
RX Series DeviceNet Communications Unit
3G3AX-RX-DRT-E
80 × 67 × 49 mm
Approx. 170 g
–10 to 50°C (with no freezing or condensation)
20% to 90%
–20 to 65°C (with no freezing or condensation)
5.9 m/s
500 VAC (between isolated circuits)
At a maximum altitude of 1,000 m (without corrosive gases or dust)
EN61800-3: 2004 (2004/108/EC) Second environment, Category C3
EN61800-5-1: 2007 (2006/95/EC) SELV
IP20
DeviceNet
DeviceNet conformance test
AC drive (0x02)
Remote I/O: Master-Slave connection
Poll
Explicit message
Conforming to the DeviceNet specifications
11 to 25 VDC (50 mA max., 20 mA typ.)
Node address MAC ID 0 to 63, set via Inverter parameter P192
125, 250, or500 kbps
Automatic baud rate detection by Master Unit
Supported, set via Inverter parameter P046
Basic Speed I/O (Output assembly 20, Input assembly 70)
Extended Speed I/O (21, 71)
Extended Speed and Torque Control (123, 173)
Special I/O (100, 150)
Extended Control I/O (101, 151)
Extended Control I/O and Multi-function Input Monitor (101, 153)
Flexible Format (139, 159)
Extended Speed and Acceleration Control (110, 111)
In case the DeviceNet Master Unit is configured using user allocation, only the
input/output pairs can be configured.
Dependent on Inverter model
Specifications
2
(0.6 G), 10 to 55 Hz
12 Options
12
12 - 63

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents