10 Troubleshooting

10-2 Warning Function

The following table shows the relationship between the displayed warning code and the parameter
correction.
Warning code
W001
1st Frequency Upper Limit (A061)
W002
1st Frequency Lower Limit (A062)
Output Frequency Setting/Monitor (F001),
W005
1st Multi-step Speed Reference 0 (A020)
Output Frequency Setting/Monitor (F001),
W015
1st Multi-step Speed Reference 0 (A020)
1st/2nd Frequency Upper Limit
W019
(A061/A261)
Output Frequency Setting/Monitor (F001),
W025
1st Multi-step Speed Reference 0 (A020)
W029
1st Frequency Lower Limit (A062)
W031
1st Frequency Upper Limit (A061)
W032
1st Frequency Lower Limit (A062)
Output Frequency Setting/Monitor (F001),
W035
1st Multi-step Speed Reference 0 (A020)
W037
Jogging Frequency (A038)
Output Frequency Setting/Monitor (F001),
W085
1st Multi-step Speed Reference 0 (A020)
Multi-step Speed Reference 1 to 15
W086
(A021 to A035)
W091
Free V/f Frequency 7 (b112)
W092
Free V/f Frequency 7 (b112)
W095
Free V/f Frequency 7 (b112)
W201
2nd Frequency Upper Limit (A261)
W202
2nd Frequency Lower Limit (A262)
Output Frequency Setting/Monitor (F001),
W205
2nd Multi-step Speed Reference 0 (A220)
Output Frequency Setting/Monitor (F001),
W215
2nd Multi-step Speed Reference 0 (A220)
Output Frequency Setting/Monitor (F001),
W225
2nd Multi-step Speed Reference 0 (A220)
W231
2nd Frequency Upper Limit (A261)
W232
2nd Frequency Lower Limit (A262)
Output Frequency Setting/Monitor (F001),
W235
2nd Multi-step Speed Reference 0 (A220)
Output Frequency Setting/Monitor (F001),
W285
2nd Multi-step Speed Reference 0 (A220)
W291
Free V/f Frequency 7 (b112)
W292
Free V/f Frequency 7 (b112)
W295
Free V/f Frequency 7 (b112)
Output Frequency Setting/Monitor (F001),
W305
3rd Multi-step Speed Reference 0 (A320)
Output Frequency Setting/Monitor (F001),
W335
3rd Multi-step Speed Reference 0 (A320)
Output Frequency Setting/Monitor (F001),
W385
3rd Multi-step Speed Reference 0 (A320)
10 - 12
Warning display conditions
>
1st Maximum Frequency (A004)
>
1st Maximum Frequency (A004)
>
1st Maximum Frequency (A004)
>
1st Frequency Upper Limit (A061)
<
Orientation Speed Setting (P015)
<
1st Frequency Lower Limit (A062)
<
Orientation Speed Setting (P015)
<
Starting Frequency (b082)
<
Starting Frequency (b082)
<
Starting Frequency (b082)
<
Starting Frequency (b082)
Jump Frequency 1/2/3 ± Jump Frequency Width 1/2/3
<>
(A063/A065/A067) ± (A064/A066/A068)
Jump Frequency 1/2/3 ± Jump Frequency Width 1/2/3
<>
(A063/A065/A067) ± (A064/A066/A068)
<
1st Frequency Upper Limit (A061)
<
1st Frequency Lower Limit (A062)
<
1st Multi-step Speed Reference 0 (A020)
>
2nd Maximum Frequency (A204)
>
2nd Maximum Frequency (A204)
>
2nd Maximum Frequency (A204)
>
2nd Frequency Upper Limit (A261)
<
2nd Frequency Lower Limit (A262)
<
Starting Frequency (b082)
<
Starting Frequency (b082)
<
Starting Frequency (b082)
Jump Frequency 1/2/3 ± Jump Frequency Width 1/2/3
<>
(A063/A065/A067) ± (A064/A066/A068)
<
2nd Frequency Upper Limit (A261)
<
2nd Frequency Lower Limit (A262)
<
2nd Multi-step Speed Reference 0 (A220)
>
3rd Maximum Frequency (A304)
<
Starting Frequency (b082)
Jump Frequency 1/2/3 ± Jump Frequency Width 1/2/3
<>
(A063/A065/A067) ± (A064/A066/A068)