4 Parameter List
4-1

Monitor Mode

The inverter by default displays the content of the parameter d001at power-on. To monitor the desired
parameter, change the setting in the Initial Screen Selection (b038).
4-1-1

Group d

Parameter
Function name
No.
d001
Output Frequency
Monitor
d002
Output Current
Monitor
d003
RUN Direction
Monitor
d004
PID Feedback
Value Monitor
d005
Multi-function
Input Monitor
d006
Multi-function
Output Monitor
d007
Output Frequency
Monitor
(After Conversion)
d008
Real Frequency
Monitor
d009
Torque Reference
Monitor
d010
Torque Bias
Monitor
d012
Output Torque
Monitor
d013
Output Voltage
Monitor
4 - 2
Monitor or data range
0.00 to 99.99
100.0 to 400.0
0.0 to 999.9
1000. to 9999.
F: Forward
o: Stop
r: Reverse
0.00 to 99.99
100.0 to 999.9
1000. to 9999.
1000 to 9999
(10000 to 99990)
Γ100 to Γ999
(100000 to 999000)
(Enabled when the PID function is
selected)
ON
FW
OFF
Multi-function
S8
S7 S6
S5 S4
S3 S2
S1
input terminals
(OFF) (ON) (OFF) (OFF) (OFF) (OFF) (ON) (ON)
Multi-function
output terminals
MA P5 P4
P3 P2
P1
(OFF) (OFF) (OFF) (OFF) (ON) (ON)
Relay output terminals
0.00 to 99.99
100.0 to 999.9
1000. to 9999.
1000 to 3996
(10000 to 39960)
[Output Frequency (d001) x
Frequency Conversion Factor
(b086)]
0.00 to 99.99 (Forward)
100.0 to 400.0 (Forward)
–99.9 to –00.0 (Reverse)
–400. to –100. (Reverse)
–200. to 200.
–200. to 200.
–200. to 200.
0.0 to 600.0
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Changes during
Default
operation
data
Normal
Enabled
Display
: ON
ON
: OFF
OFF
Display
: ON
ON
: OFF
OFF
Enabled
Unit
Page
b031 = 10
Enabled
Hz
7-2
A
7-2
7-2
7-3
7-3
7-4
Enabled
7-4
Hz
7-5
%
7-5
%
7-5
%
7-6
V
7-6